Pfauen
Stage and audience
Stage Dimensions
Total Floor Area
240 m2
Stage Depth
Safety Curtain to Firewall
14.80 m
Safety Curtain to Base Line
2.02 m
Base Line to Last Flybar
11.88 m
Forestage Depth
Safety Curtain to Front Edge of Orchestra
1.40 m
Stage Width
Total Width
14.70 m
Stage Height
+/- 0 to Grid
16.40 m
Stage Edge
1.10 m
Orchestra Pit
-2.44 m
Below-Stage
-2.44 m
Architectural Portal
Width
8.98 m
Height
5.10 m
Proscenium Towers and Proscenium Bridge
Height
max. 5 m
Width
fixed 8.70 m
Fly Galleries
Fly Gallery 1
6.50 m
Fly Gallery 2
8.96 m
Fly Gallery 3
12.05 m
Clear opening between galleries left/ right
11.60m
Side Stage
Width
10.00 m
Depth
15.50 m
Gate Height to Side Stage
5.70 m
Side Stage Gates
Width
6.25 m
Height
6.00 m
Delivery Gate
Width
3.10 m
Height
3.20 m
Ramp Height (adjustable)
0.95 m
Seating Capacity
Stalls
491 Seats
Balcony
170 Seats
Balcony Boxes (left)
25 Seats
Balcony Boxes (right)
18 Seats
Folding Seats
42 Seats
Wheelchair Positions
2 Seats
Total
746 + 2 Seats
Point of view
Stage Technical Systems
Facilities Section
Transport Platform
Dimensions:
10.00 m x 3.00 m
Hub:
-8.74 m, +1.65 m, 0 – 0.40 m/s
Loads:
statisch 500 kg/m2 dynamisch 250 kg/m2
Orchestra Platform
Dimensions:
8.97 m x 1.34 m
Hub:
-2.44 m, +0.00 m. 0 – 0.20 m/s
Loads:
statisch 500 kg/m2 dynamisch 250 kg/m2
Miscellaneous:
Slanted Position max. 12%
Dimensions:
12.42 m x 1.13 m
Hub:
+/- 0.00 m - + 5.36 m
Loads:
7 Compartments 1000 kg each
Floor Slabs 42 Units
Dimensions:
1.00 m x 1.00 m
Loads:
500 kg/m2
Miscellaneous:
removable
Obermaschinerie
Forestage Flybar 1 - VBZ 1
Dimensions:
9.1 m
Hub:
+0.2 m, + 6.35 m, 0.15 m/s
Loads:
300 kg
Miscellaneous:
fixed lighting installation
Forestage Flybar 2 - VBZ 2
Dimensions:
9.2 m
Hub:
+ 0.2 m, (+5.16 m) 5.38 m, 0.15 m/s
Loads:
300 kg
Auditorium Lighting Flybar
Dimensions:
7.98 m
Hub:
0.10 m/s
Loads:
250 kg
Safety Curtain
Dimensions:
9.30 m x 5.50 m
Hub:
0.10 m/s
Loads:
250 kg
Main Curtain (Velour/Red)
Hub:
0.10 m/s
Miscellaneous:
Motor-Driven Horizontal and Vertical
Forestage 1 Flybar (guided) – V2
Dimensions:
11.70 m - 15.20 m
Hub:
+0.20 m, +11.50 m, 0 - 1.50 m/s
Loads:
350 kg
Miscellaneous:
Flybar ø 60 mm
Forestage 2 Flybar (guided) – V2
Dimensions:
11.70 m x 15.20 m
Hub:
+0.20 m, +11.50 m, 0 - 1.50 m/s
Loads:
350 kg
Miscellaneous:
Flybar ø 60 mm
Acoustic Curtain
Dimensions:
11.70 m x 15.00 m
Hub:
+0.20 m, +14.80 m,0 - 1.50 m/s
Loads:
1000 kg
Miscellaneous:
Ladder truss ø 60 mm
Additional Lighting Bridge Drive (Smartdrive)
Hub:
+0.20 m, +14.80 m, 0.10 m/s
Loads:
100 kg
Proscenium bridge
Hub:
+0.20 m, +5.00 m, 0.10 m/s
Loads:
2500 kg
Point Hoists 15 x
Hub:
+0.20 m, +15.24 m, 0 - 1.50 m/s
Loads:
350 kg
Miscellaneous:
Freely Positionable
Machine Flybars 46 Units
Dimensions:
10.00 m (11.40 m Auszug)
Hub:
+0.20 m, + 15.05 m, 0 - 1.50 m/s
Loads:
350 kg
Miscellaneous:
Ladder truss ø 60 mm / Flybar Interval 185 mm
Lighting bridges 3 Units
Hub:
1.00 m, +13.00 m, 0 - 0.70 m/s
Loads:
900 kg
Panorama Flybar (right/ left)
Hub:
+0.20 m,+15.24 mm 0 - 1.50 m/s
Loads:
350 kg
Miscellaneous:
Flybar ø 60 mm
Under Gallery Flybar (right/ back/ left)
Loads:
250 kg
Miscellaneous:
Flybar ø 60 mm
Side Stage Gate (left)
Dimensions:
6.25 m x 6.00 m
Hub:
±0.00 m, +5.70 m, 0.10 m/s
Lighting Technology
Lighting Control
Auditorium Space, upper left
Lighting Control System
MA Lighting grandMA2
Network
Netzwerk
MA-Net and sACN with Multiple Nodes and Switches
Power Circuits
3 kW DIM
(excl. Auditorium and Working Light) 401 Circuits
6 kW DIM
86 Circuits
10 kW DIM
20 Circuits
10 A SWITCHES 1-Phase
174 Circuits
13 A NON-DIM 1-Phase
56 Circuits
16 A NON-DIM 1-Phase
switched via contactors 31 Circuits
16 A NON-DIM 3-Phase
switched via contactors 21 Circuits
32 A NON-DIM 3-Phase
switched via contactors 17 Circuits
63 A NON-DIM 3-Phase
switched via contactors 6 Circuits
HMI Vorschaltgeräte (Arri 1.2, 2.5, 4 kW)
12 Units
*
CAD Lighting plam with LED-, Thungsten- und HMI-Geräten available.
Sound Technology
Sound Control
Balcony Box Nr. 6, right
Mixer
STUDER Vista V
Effects
Lexicon PCM96 / TC2000
Players
Ableton Live
Stage Public Address Systems
K&F CA106/ Line 212/ CA 1215/ SW 118
Auditorium Public Address Systems
Bass
d&b E15X / B2
Mobile PA Systems
K&F CA1215/ K&F CA106/LA 108/LA 112/d&b Q7
Delay- and Effect PA System
K&F CA106
*
Various Junction Boxes on Stage and in Auditorium
Video Technology
Video Control
Auditorium Control Room, upper right
Player
Medienserver AV Stumpfl Wings RX
Beamer Balkon side fixed
Panasonic PT-RZ970
Stage Manager's system
Location
Curtain Area, right
Stage Manager’s Desk
24 light cues
-
General Call, Selective Call, Paging System, Monitor System
-
Cameras (Infrared / Zoom / Total)
-
Riedel Intercom System
Subtiteling System
Software
Panthea Spectitular
Position
projection on 3 screens (fixed)
Utilities
Water (warm + cold)
Stage + Below Stage ea. 1x left/ right
Sewer
Below Stage 1x left/ right
Compressed Air Outlet (7 Bar)
Below Stage, Stage, Gallery 1
HVAC System
available in Public Seating Area
Fire Protection
-
Fire Detection System
-
Safety Curtain (Water Drench System)
-
Water Curtain, Smoke Extraction Stage/Auditorium, Fire Hose Cabinets